FF ONE 1-9 LOOP

FF ONE 1-9 LOOP

INTELLIGENT FIRE ALARM PANEL


FEATURES

  • Maximum performance with 32-bit micro processor
  • Graphic touch screen
  • 20 characters
  • Different scenario options
  • Full digital protocol
  • Addressing up to 240 devices in 1 loop
  • Conform to EN54-2 and EN54-4
  • 1000 event memory capacity

LOOP OPTIONS

FF ONE-1L 1 Loop Intelligent Addressable Fire Alarm Control Panel, 1 loop x 240 Addresses, 4.3” Touch Screen, Network Option, Up to 9 Loop
FF ONE-3L 3 Loop Intelligent Addressable Fire Alarm Control Panel, 3 loop x 240 Addresses, 4.3” Touch Screen, Network Option, Up to 9 Loops
FF ONE-5L 5 Loop Intelligent Addressable Fire Alarm Control Panel, 5 loop x 240 Addresses, 4.3” Touch Screen, Network Option, Up to 9 Loops
FF ONE-7L 7 Loop Intelligent Addressable Fire Alarm Control Panel, 7 loop x 240 Addresses, 4.3” Touch Screen, Network Option, Up to 9 Loops
FF ONE-9L 9 Loop Intelligent Addressable Fire Alarm Control Panel, 9 loop x 240 Addresses, 4.3” Touch Screen, Network Option,Up to 9 Loops
Operating voltage 230V AC
Operating Current 1A
Fire Relay 24V, 1A
Fault Relay 24V, 1A
Sounder Output 24V, 0,5A
Operating temperature 0°C ~ +50°C
Dimensions 410x410x120

REPETITION PANEL FF ONE KBD

    FEATURES

  • Graphic touch screen (480x272 TFT 4.3“)
  • 14 Front LED
  • 2 RS 485 for connection
  • 1 RS 232 / micro USB for programming
  • Operating Temperature: 5 ° C / + 40 ° C
  • Power supply: 24Vdc
  • Power consumption: 100mA

EXPANSION CARD

  • The FF One Expansion Card allows you to increase the FF One detection capacity from 2 to a maximum of 9 at a time, in terms of increasing the number of loops.
  • Technicial Specifications:
  • 2-loop expansion card for FF One
  • EN54-2 standard certificated device
  • With result error management, loops can be defined as open or closed loops.
  • Maximum number of devices per loop: 240
  • Installation in the unit in the specific connection of the motherboard.
  • No 2 programmable video alarm output relay.
  • Multiple protocols Teledata Apollo and Wizmart.

NETWORK CARD

  • CAN BUS connection
  • Up to 32 control panels in network
  • Up to 50 Kbps data transmission
  • Fault tolerant connection provides the necessary communication by making ring connection in case of fault
  • Compatible with Olympia fire panel
  • Built in Olympia fire panel internally
  • Cable length up to 1.2Km
  • Consumption: 250mA max

ZONE LED ONE 56

  • Card for area alarm management
  • n° viewable area: 56 domain ledED
  • Operating Temperature: 5 ° C / + 40 ° C
  • Dimensions: 219x58mm